К продукции

The basic set of hardware and software

A_9878-1.Wireless amplifier unit ABP-2 (base unit)

It has a built-in wireless module "Bluetooth 5.0" (Bluetooth low energy) for communication with a PC and additional wireless units, modules and sensors from the set. The base unit has one Micro-8M input connector for two bipolar or two monopolar EEG leads or two polygraphic sensors/electrodes, as well as for the I2C interface (digital sensors). The unit has a built-in motion sensor and a multifunctional button. On the back of the unit there is a button for connecting a disposable neutral electrode or conductor of an N electrode (A_1150).

Specifications

The set with ABP-2 includes:

A_5125. Charger Cable (Micro 8M)
For ABP-2

The charging cable has USB-A and Micro-8M connectors and is used to connect the purchased charger to the ABP-2 base unit and the Poly-2 module (if available).

A_1150. Neutral wire (with “snap” connector Ø 12 mm and with connector “socket” Ø 12mm)

It can be used in ABP-2 and Poly-2 (if available) units when they are freely placed (not fixed with a disposable ECG electrode) and the connector socket on the module and block housings is connected by a wire with the N electrode conductor button to remove the socket for the N electrode to the required distance and fix the disposable ECG electrode on the skin.

A_0375. Simulator IS-Micro
For ABP-2 and Poly-2 (ifavailable)

The simulator has an 8-pin EEG connector (Micro-8M) and is connected to the corresponding socket of the ABP-2 or the Poly-2 units.

A_2348. Software "Cardfile"

The software is designed to save and structure data on conducted research in an electronic file (database), search for the necessary studies according to specified criteria, save the analysis results as attached files (protocol on the conducted research, export files to Excel and Word, screenshots with graphs and diagrams), generate reports on conducted studies.

View details

A_4029.Wireless PC adapter IB-USB

The IB-USB interface unit ensures the operation of the communication channel of the IB-USB unit with the PC of the System via the USB interface and the operation of 10 information communication channels of the wireless interface "Bluetooth 5.0" of the IB-USB unit with the Base units ABP, as well as additional modules and devices of the System, ensuring mutual synchronization of data flows from them.

A_3889. Software functional biocontrol with biofeedback training “REHACOR”

The software provides procedures for functional biofeedback (biofeedback training) to train self-regulation skills and control of various physiological parameters. The software includes a library of training scenarios with BFB with training groups of various purposes.
It provides the possibility of creating new training scenarios and including them in the software as additional trainings.
Together with the software "REHACOR", you should purchase the Main library of training scenarios with BFB, which includes 7 groups of training scenarios and a set of necessary sensors and accessories for them. The consumer, in addition to the Main Library, can purchase the required groups of training scenarios for various purposes.

View details

Additional set of equipment

A_9878. Wireless amplifier unit Poly-2

It is used:

  • in the trainings of the neurofeedback;
  • with additional software "ENCEPHALAN- MPA" for analyzing signals through polygraphic channels together with EEG signals;
  • with EEG and EP studies "ENCEPHALAN-AVS" using audiovisualstimulation.
Specifications

Set of wireless amplifier unit Poly-2 includes:

A_5125. Charger Cable(Micro 8M) For Poly-2

The cable has USB-A and Micro-8M connectors and is used to connect the purchased charger to the ABP-2 base unit or additional the Poly-2 unit.

A_1150. Neutral wire (with “snap” connector Ø 12 mm andwith connector “socket” Ø 12 mm) (3pcs)

It can be used in ABP-2 and Poly-2 (ifavailable) units when they are freely placed, not fixed with a disposable ECGelectrode, and the connector socket on the module and block housings isconnected by a wire with the N electrode conductor button to remove the socketfor the N electrode to the required distance and fix the disposable ECG electrodeon the skin.

A_0375. Simulator IS-Micro
For ABP-2 or Poly-2 (if available)

The simulator has an 8-pin EEG connector (Micro-8M) and is connected to the corresponding socket of the ABP-8 or the Poly-2 units.

General additional accessories

B_0881. Charger
(
specifythe type when order)

Designed for charging wireless devices of the system using a charger cable (A_5125) for the ABP-2 unit or POLY-2 unit (if available), as well as using a charger cable (USB-C, A_9447-21_KM) for the electro-vibro-tactile module (if available) or balance platform (if available).

А_2329. SW key (USB adapter)

Provides the possibility of using the purchased software on an additional user's computer, including in the network version for processing the received data.

A_2129. Adhesive paste Unipaste

For adhesive cup electrodes (120 gr.).

A_1302. Adhesive plaster
(OMNIFIX elastic or similar)

For fixing electrodes and sensors. Size 10 m x 5 cm

A_2714. Disposable ECG Electrodes
(used for recording ECG, EMG, EOG, in a package of 50 pcs.)

Computer equipment and additional components

A_2380. Real–time computer station (portable)

Minimum characteristics of a portable PC (no worse):Intel Core i5 processor type, 8GB RAM, 512 GB SSD, 14" display and larger, HDMI port, minimum 2 USB ports, Windows 10 and later, a mouse.It requires an integrated Iris video card or a discrete video card in the PC.Connection of one additional monitor and VR goggles is required.

Warning! When purchasing, it is necessary to coordinate the parameters with the manufacturer.

If the Customer wishes to choose an improved version of computer equipment, it is mandatory to inform the supplier about this and coordinate the characteristics of computer equipment with the manufacturer.

A_8585  VR goggles

They provide the perception of audiovisual information and immersion in 4K multimedia for training with BFB on a 120-inch virtual screen.

A_5109. Kaspersky Internet Security antivirus software

Recommended for virus protection

A_4319. MS Office.

Word and Excel are required

A_2604. Portable computer carrying bag

At Customer’s choice.

A_0687. Additional monitor (23” and larger)

The monitor is necessary for effective work with Software functional biocontrol with biofeedback training “REHACOR” and "ENCEPHALAN-AVS".

A_4300. Computer acoustic system 2.1 or 3.1

Purchased at Customer’s choice for an additional monitor

A_5565. Digital widescreen TV

at Customer’s choice

A4 laser printer

at Customer’s choice

The main library of training scenarios with BFB

Group 020. Тemperature biofeedback trainings

Group 030. Electromyographic biofeedback trainings

Includes trainings:

Sensors are used:

  • Envelope EMG Sensor (double) (Micro-8)
    Used in scenarios 0301_10 and 0302_10
A_4142-1
  • Sensor EEMG2/EEMG2 (Micro-8M)
    Used in scenarios 0314_10, 0315_10, 0316_10
A_5575-0

Group 050. Pulse and heart rate biofeedback trainings

Includes trainings:

Sensors are used:

  • ECG-Cable (witn N electrode) (Micro-8)
    Used in scenarios 0501_10 and 0502_10
A_8302-2
  • SkC/PPG Sensor (Micro-8M) (SkC sensor is not used)
    Used in scenarios 0511_10, 0512_10, 0816_10
A_5430-1
  • ECG/RespEf Sensor (Micro-8M)
    Used in a scenario  0504_10
A_5691-0
  • Sensor SkC/PPG*+RespEf (Micro-8M) (SkC sensor is not used)
    Used in a scenario 0815_10
A_5430-2

Group 060. Neurofeedback trainings

Includes trainings:

Sensors are used:

  • EEG Bipolar Lead (Micro-8) With N electrode and cup adhesive electrodes
    Used in scenarios 0601_20, 0601_22, 0601_30, 0601_32, 0611_10, 0612_10, 0612_11, 0604_10, 0627_10.
A_4031-3
  • EEG/EEG Sensor (Micro-8M)
    Used in scenarios 0600_10, 0602_10, 0602_11
A_5577-0

Group 070.  Respiratory biofeedback trainings

Group 080.  Blood circulation biofeedback trainings

Group 090.  Electrodermal biofeedback trainings

Прослойка

Training groups of “REHACOR” with BFB SW, additionally supplied to the main library.

Group 010.  Assessment tests of the current psychophysiological status

Group 040.  Temperature-electromyographic biofeedback trainings

Includes trainings:

Sensors are used:

  • EEG/EMG/Т* Sensor (Micro-8M)
    Used in a scenario 0401_10
A_6063-0
  • EMG/Т* Sensor (Micro-8M)
    Used in a scenario 0403_10
A_9186-0
  • EMG/Т*/Т* Sensor (Micro-8M)
    Used in a scenario 0405_20
A_9544-0
  • EEMG2/EEMG2+T*+T* Sensor (Micro-8M)
    Used in a scenario 0406_10
A_5575-2

Group 080. Blood circulation biofeedback trainings - BP

Group 081. Resonant frequency based heart rate variability biofeedback trainings

Includes trainings:

A sensor is used:

  • SkC/PPG*+RespEf Sensor  (Micro-8M) (SkC sensor is not used)
    Included in the main library of training scenarios.
    Used in all scenarios of this group
A_5430-2

Group 060. Personalized neurofeedback training based on IAPF (individual Alpha Peak Frequency)

Includes trainings:

A sensor is used:

  • EEG Bipolar Lead (Micro-8)(with N electrode and cup adhesive electrodes)
    Included in the main library of training scenarios.
    Used in all scenarios of this group
A_4031-3

Group 230. BFB trainings with EEG coherence

Группа 230. Тренинги с БОС по когерентности ЭЭГ
The BFB trainings of this group are designed to regulate the values of EEG coherence - "functional connectivity" between the pairs of EEG derivations selected by the instructor in a certain frequency range of the EEG to bring it to an optimal level that takes into account the recommended normative values of coherence based on carried out functional tests and literature data. Before conducting the training, the instructor must select pairs of EEG derivations and the EEG frequency range for the subject based on previously conducted functional studies and enter these data in the panel on the instructor's monitor.Trainings can be used for teaching children reading and writing skills, for autism spectrum disorders, mental retardation, anxiety, neuroses, depressive disorders.For healthy people, BFB trainings are carried out in order to increase the success of performing various cognitive or motor tasks, as well as to reduce negative manifestations in various functional disorders of the central nervous system.The instructor can select trainings to increase or decrease coherence or sign-changing trainings which differ from each other in different content of audio (tempo, melody) and visual (playback speed) feedback images, which can help the client to achieve the target settings.

Includes trainings:

for EEG coherence increase:

for EEG coherence decrease:

for bidirectional training of EEG coherence:

A sensor is used:

  • A_5577. EEG/EEG Sensor (Micro-8M)
    Used in all scenarios of this group
А_5577-0

Group 210. Multimodal biofeedback trainings

Includes trainings:

Sensors are used:

  • SkC/PPG*+EEG+RespEf* Sensor (Micro-8M) (SkC sensor is not used)
    Used in scenarios 0621_11 и 2102_10
A_5430-4
  • EEG/EEMG2 Sensor (Micro-8M)
    Used in a scenario 0623_10
A_8273-0
  • SkC/PPG*+EEG Sensor  (Micro-8M) (SkC sensor is not used)
    Used in a scenario 0625_10
A_5430-5
  • EEG/EEG+PPG* Sensor (Micro-8M) (SkC sensor is not used)
    Used in a scenario 1030_10
A_5577-1
  • SkC/EEMG2/Move* Sensor  (Micro-8M)
    Used in a scenario 1202_10
A_8911-0

Group 091. Stress resistance trainings with electrical stimulation

Includes trainings:

Sensors are used:

  • Module electro-vibrotactile (MEV)
    Used in conjunction with the ABP-2 unit (and the connected sensor) in scenarios 0903_10 and 0904_10 Includes a strap on the forearm
A_7045
  • SkC/PPG*+EEMG2+T* Sensor (Micro-8M) (PPG sensor is not used)
    Used in a scenario 0903_10
A_5430-3
  • SkC/PPG* Sensor  (Micro-8M)(PPG sensor is not used)scenarios.
    Used in a scenario 0904_10
A_5430-1

Group 100. Neurofeedback trainings advanced

Includes trainings:

In this group, the ABP-2 unit and the Poly-2 module are used together, to each of which a combined sensor is connected (the first to the ABP-2, the second to the POLY-2):

For trainings 1001_10 –
  • EEG/EEG Sensor (Micro-8M)(with a common referent and N electrode)
A_5577-2
  • EEG/EEG Sensor (Micro-8M)
A_5577-2
For training 1010_10 –
  • EEG/EEG Sensor (Micro-8M)
A_5577-0
  • ECG/SkC/PPG* Sensor (Micro-8M) (PPG sensor is not used)
A_5570-1
For training 1011_10 –
  • EEG/EEG Sensor (Micro-8M)(with a common referent and N electrode)
A_5577-2
  • EEG/EEG Sensor (Micro-8M)
A_5577-2
For training 1012_10 –
  • EEG/EEG+PPG*+Т* Sensor (Micro-8M) (with common hemispheric referents and additional N electrodes).(SkC sensor is not used)
A_5577-4
  • EEG/EEG+RespEf* Sensor (Micro-8M) for Poly-2
A_5577-3
For training 0626_10 –
  • EEG/EEMG2 Sensor (Micro-8M)
A_8273-0
  • Sensor SkC/PPG*+T* (Micro-8M) (PPG sensor is not used)
A_5430-7

Group 200. BFB Rhythms

Includes trainings:

Test for assessing the ability to perceive and reproduce sound patterns:

Trainings with a setting rhythm:

Sound pattern reproduction trainings:

A sensor is used:

  • Sensor Tap/synchronization sensor audio (Micro-8M) Used in scenarios of this group
A_1015-0

Group 300. Biofeedback trainings for children

Группа 300. Тренинги с БОС для детей
The purpose of "Alpha-stimulating trainings"in children is to increase the alpha activity of the brain, which contributesto the development of mental relaxation skills, normalization of the EEGstructure. Trainings can be used for various sleep disorders, headaches, ANSdisorders, as well as functional disorders of the central nervous system.The goal of "Cognitive training forchildren" is to improve cognitive and motor functions, reduce anxiety inpsychological disorders, attention deficit hyperactivity disorder (ADHD), aswell as with a decrease in the level of arbitrary regulation of attention andbehavior.Special trainings forchildren are designed to teach the skills of diaphragmatic breathing and theformation of a new respiratory stereotype with the predominance of abdominalbreathing over thoracic one.

Includes trainings:

Sensors are used:

  • A_4031-3. EEG Bipolar Lead (Micro-8)(with N electrode and cup adhesive electrodes)
    Included in the main library of training scenarios.
    Used in scenarios 0653_10, 0653_20, 0661_10, 0662_10, 0662_20, 0663_10, 0664_10
A_4031-3
  • A_5577. EEG/EEG Sensor (Micro-8M)  Included in the main library of training scenarios.
    Used in scenarios 0654_10 и 0654_20
A_5577-0
  • A_5689. RespEf/RespEf Sensor (Micro-8M) Included in the main library of training scenarios.
    Used in scenarios 0721_20 и 0721_10
A_5689-0

Group 140. BFB Balance trainings

Includes trainings:

Balance-training for sustainability:

Balance-training for movement coordination:

A sensor is used:

  • Wobble platform It is used in all BFB scenarios of this group
A_9896

Group 150. Adaptive model of combined operator activity (AMOA)

Includes trainings:

Sensors are used:

  • A_2073-2. ECG-Cable (Micro-8) (two-wire with Ø 12 mm “socket” connectors for disposable and reusable electrodes) Used in a scenario 1500_10
A_2073-2
  • A_5570-1. ECG/SkC/PPG* Sensor (Micro-8M) is connected to ABP-2Included in the main library of training scenarios.
    Used in scenario 1513_10, 1501_10.
A_5570-1
  • A_5430-5. SkC/PPG*+EEG Sensor (Micro-8M) Used in scenario 1511_10.
A_5430-5
  • Attention! A computer mouse or joystick (A_5590-01, section computing equipment and additional components) can be used for the training, which must be purchased additionally.
A_5590-01

Group 190. BFB-trainings with a hand grip dynamometer

Includes trainings:

Sensors are used:

  • Muscle Tension Sensor (handgrip) Used in scenarios 1901_10, 1901_20, 1901_30, 1902_10, 1902_20, 1902_30, 1904_10, 1903_10, 1903_20, 1903_21
A_6649-2
  • EEG/HGD* Sensor (Micro-8M) Used in scenarios 1905_10, 1905_20, 1904_20, 1906_10
A_8224-0

A_2577-45. Efficacy evaluation of BFB trainingspart of Software for functional biocontrol  with biofeedback training “REHACOR”

The software "Efficacy evaluation of BFB trainings" provides an assessment of the effectiveness and success of the BFB training in the processing mode in post-real time, in particular:
• quantifying the success of each managed stage of the session;
• quantitative assessment of the success of the BFB training session;
• quantitative assessment of the effectiveness of the full course of the conducted BFB trainings.
Monitoring the success of the BFB training is necessary for the instructor to confirm that the goals of the BFB training session are achieved as it progresses or at least tend to achieve the goal. Success control is also needed to be able to timely identify the absence of expected positive results or the appearance of some negative trends in the dynamics of physiological indicators in order to be able to adjust the course of the BFB training.
The effectiveness of the BFB training course as a whole is assessed on the basis of the average success index of all sessions included in this course and the "cumulative effect". The cumulative effect is estimated on the basis of identifying the tendency of accumulating physiological shifts of controlled parameters from session to session and characterizes the severity of long-term modification of the mechanisms of physiological regulation.
The software "Efficacy evaluation of BFB trainings" provides the formation of a verbal report on the course of the BFB training, with the inclusion of two or three-dimensional forms of representations of the results, for example, in the form of graphs for the session, graphs for the course, surface 3D diagrams of the course performance and conclusions on controlled parameters.
More detailed
Прослойка

Add-ons that extend the functionality of the execution REHACOR-NEXT

A_1531-11 Software for objective psychological analysis and testing «EGOSCOP» and a test library

Including the following groups:

  • multifactorial personality questionnaires;
  • interpersonal relationship questionnaires;
  • questionnaires of motivational features;
  • questionnaires of mental states;
  • self-attitude questionnaires;
  • temperament questionnaires;
  • questionnaires of abilities and values;
  • psychophysiological tests;
  • cognitive tests;
  • projective tests.

The software allows you to expand the library of drawing or text projective techniques, as well as various questionnaire tests.

Additional features for the auto-documentation of the testing process and special processing expand the user's capabilities in terms of an objective assessment of test results and allow the use of calculated statistical information about physiological and pictographic reactions for additional socio-psychological and cognitive-somatic interpretation of the conducted studies.

The list of tests is provided upon request, it is possible to change the composition of tests in agreement with the Customer.

It requires:

  • A_4074. Pen Display – electronic tablet Wacom CINTIQ 16 type (purchased individually);
  • MS Office as part of the personal computer software.

The set includes:

A_5570-1. SkC/ECG/PPG Sensor (Micro-8М)

to register physiological signals using the ABP-2 unitSkC, ECG, PPG signals are recorded

A_4074. Pen Display (electronic tablet Wacom CINTIQ 16 type or an analog)

It is a device for touch-sensitive accurate graphical input of information.Connects to a personal computer.When conducting psychophysiological research and psychological testing, it allows to:

  • register pictographic data characterizing the psychomotor activity of the subject;
  • produce synchronous auto-documentation of testing information (drawing arbitrary graphic images by the subject, writing words, numbers, etc.) with the parameters of the motor skills of the hand (pressure on the pen, the delay time before drawing graphic images and the delay time before moving to the next stage).
  • register the search activity of the subject when performing tests.

Attention: If you purchase it yourself, the type of device must be agreed with MEDICOM MTD Ltd.

A_6423. Oculomotor tubus and a corresponding test in the library

It is used for Critical flicker fusion and distinguishing tests (CFFF, CFDF), in order to assess the functional state of the cortical part of the visual analyzer and the central nervous system, as well as to assess the degree of inertia of mental processes and functional asymmetry.

A_6354. Pad for tapping test and an additional test in the EGOSCOP library

It is used for tapping test to determine the strength and mobility of the nervous system.Allows you to register, in addition to the dynamics of the frequency of hits, also the dynamics of the hit force.

A_1964. Heart rate variability analysis «HRV»

Used for:

  • as a screening test for psychophysiological studies
  • evaluation of the characteristics of the initial vegetative tone, vegetative reactivity and vegetative support of activity;
  • assessment of the adequacy of physical and psycho-emotional loads in educational and production processes

It can be used both independently and as an accompanying and related to the main testing in scientific non-medical research.

  • А_4740.  Bipolar ECG cable with neutral electrode (total of 3 electrodes) for disposable electrodes. Length 1.5 m
More detailed

The set includes:

A_2714. Disposable ECG Electrodes (use for recording ECG, EMG, EOG, in a package of 30 pcs.)

А_2229. ECG Electrodes Set (clamp EEG electrodes 3 pcs.)

For use in training instead of disposable electrodes (if it is impossible to use them) using an ECG A_8302-2 cable.

A_0803. Software "ENCEPHALAN-MPA" for the multiparametric analysis of signals via polygraphic channels with EEG signals for scientific research in psychophysiology

The software provides:

  • calculation and visualization of trends reflecting the cardiocycle (cycle to cycle) dynamics of indicators of the cardiovascular, vegetative and central nervous systems on a single time scale, for visual assessment of their relationship;
  • detailed analysis of recorded signals to assess physiological shifts in response to provoking influences in order to identify weak and compensatory links in the body's systems during psychophysiological tests;
  • conducting statistical and spectral analysis, constructing histograms and/or scattergrams of the distribution of indicators for specified study fragments;
  • formation of an automatic protocol with a formalized description and tabular data reflecting the initial state and significant changes associated with functional tests.
More detailed

A_0712.  EEG and EP studies using audio-visual stimulation "ENCEPHALAN-AVS"(from the EP-studies "ENCEPHALAN-EP", the "basic" option)

SW "ENCEPHALAN-AVS" is designed to study the mechanisms of human perception and memory, emotions, attention, mental activity, with attention and memory disorders.

The main difference between an audiovisual stimulator and other types of stimulators is that AVS allows the use of stimuli with semantic content, which allows the use of ENCEPHALAN-AVS software in scientific research in cognitive psychology.

Requires:

  • additional monitor for presentation of video stimuli;
  • headphones or speakers for presentation of audio stimuli.
More detailed

The set includes:

A_9873. Button sensor

The sensor has two buttons on the body for marking events by the respondent, a built-in LED and a vibration module for presenting a light and vibrotactile stimulus to the respondent, as well as a built-in movement activity sensor and a Bluetooth 5.0 wireless module

А_4833. Optical synchronization module

The module provides registration of a synchronizing video stimulus on the PC monitor screen using a built-in optical sensor and a wireless module "Bluetooth 5.0".

Прослойка

Thank you for familiarizing yourself with REACTOR-NEXT products!

Request a commercial offer

You can order products by filling out a request for a commercial offer

Свернуть всё